Pentair intelliflo display not working.

I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however. I cannot program anything since i can't see what it is i am programming. i check out to replace the screen i need to... www.troublefreepool.com. Also, this youtube video that seem ...

Pentair intelliflo display not working. Things To Know About Pentair intelliflo display not working.

Intelliflo VS does not start turning but powers on via intellicenter easytouch2 4 firmware 2.140. I had an issue with my pump that had been working for years. It lost communications. I had a spare cable and changed it and reset the pump and get the display not active like i should but the...SWG Type. Hayward Turbo Cell (T-CELL-5) Sep 15, 2022. #18. For surge protection it is recommended to have one in each panel and where possible, one at the end device like a power bar for a computer or TV. Best you can do for pool equipment is add a Siemens Boltshield in all the panel (s). Takes 2 spaces.Pentair intelliflo pool pump display only lasted 4 years and now the part is discontinued. ... Pentair - Display quit working after 4 years and is discontinued as ...PENTAIR HOME INTEIONNET ’ If you have questions about ordering Pentair replacement parts, and pool products, please contact: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service and Technical Support, USA (8 A.M. to 4:30 P.M. — Eastern/Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site …

The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for unparalleled efficiency.Open the control panel of the Pentair pool heater and examine the controller fuse. Replace the blown fuse with a new one and turn on the pool heater to check …

Consult Pentair Water Pool and Spa, Inc. with any questions regarding this product. This product is intended for use in swimming pool applications only. Most states and local codes regulate the construction, installation, and operation of public pools and spas, and theWater Pump Pentair INTELLIFLO Operation And Set Up Instructions. (16 pages) DC Drives Pentair INTELLIFLO Installation Manual. Variable speed pump drive (4 pages) Water Pump Pentair INTELLIFLO VS+SVRS Installation And User Manual. Ultra energy efficient pump (56 pages) Water Pump Pentair IntelliFloXF Installation And User Manual.

Our client called us stating the variable speed pool pump was not turning on and they are having to turning it on manually. Their home experienced a power ou...0:00 / 13:12 Off Menu: Pentair Intelliflo Pool Pump LCD Screen Repair | see description Retro Recipes 175K subscribers 588 39K views 5 years ago Occasionally we go 'off menu' & look at things a...The IntelliFlo VSF pump provides precise flow control, which means increased efficiency, savings and performance. The pump’s innovative dual-technology desig...Pentair Intelliflo Display Not Active The Pentair Intelliflo Display is a handy device used to monitor the performance of an Intelliflo pool pump. Unfortunately, at times this display may become unresponsive and ‘not active’.

May 27, 2019 · I would purchase the newer model that has the rotatable display. There are also flow control models that allow you to set a flow rate set-point. DO NOT GET THE SVRS (safety vacuum release system) MODEL. All IntelliFlo and WhisperFlo Pentair pumps use the same wet end design. So there should be no plumbing work necessary.

The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. It is being practiced by thousands of pool owners just …

The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. It is being practiced by thousands of pool owners just like you. We are a registered 501(c)3 non-profit that is funded by user donations. Please consider Supporting TFP!Water Pump Pentair INTELLIFLO Operation And Set Up Instructions. (16 pages) DC Drives Pentair INTELLIFLO Installation Manual. Variable speed pump drive (4 pages) Water Pump Pentair INTELLIFLO VS+SVRS Installation And User Manual. Ultra energy efficient pump (56 pages) Water Pump Pentair IntelliFloXF Installation And User Manual.Brand, Pentair. FinishColor, Almond. ForUseWith, IntelliFloXF, IntelliFlo 2 VST Pumps. Includes, Keypad Cover. Item, Keypad Assembly Kit ...Jun 5, 2022 · Hi My pentair intelliflo pump won't turn on. No power. Screen is blank. Contractor's Assistant: I'll do all I can to help. How long have you been dealing with this? Today. I was opening my pool. Contractor's Assistant: Do you plan on doing the work yourself? Yes. Contractor's Assistant: Is there anything else the Pool Technician should know ... Our client called us stating the variable speed pool pump was not turning on and they are having to turning it on manually. Their home experienced a power ou...

I have “no comm” on my pump status from pentair intelliflo to pentair easytouch. Contractor's Assistant: Have you checked the wiring connections between the pump and the EasyTouch control panel? Yes, pump display says “display not active” while in auto and it becomes active in service mode#1 Hello. I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however.Jan 13, 2019 · Oceanside, CA. Jan 13, 2019. #3. Jimrahbe said: Fred, ScreenLogic remembers the last setting so it is often hard to tell if it just presenting old info.. I suspect you have lost the wireless link between the ET and the Protocol adapter.. On the outside antenna, raise the hood and see if the green power light is on and that the RX and TX lights ... Aug 28, 2017. #8. Pentair is issuing a work order to an authorized pool repair company to replace the drive since I am just in time for them to honor my 3 year warranty. By the way, Pentair has since reduced their warranty for this pump to 2 years. I suspect that is because they are failing too often within the 3 year warranty for their comfort.http://www.pentairpool.comhttp://www.poolfyi.comhttp://www.facebook.com/pages/Pentair-Aquatic-Systems/295848388965http://twitter.com/pentairpoolHeat pump troubleshooting guide for Pentair pool heaters. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Call Us Nationwide: 1-800-741-9956. ... does not work, recover the charge, remove bulb from SL, unscrew TXV head, shake it, if rattles, replace head (PN KT-45-ZGA), if not, replace TXV ...

Pool Pump not Turning On? It could be okay. Trust me on this. Don't toss that pool pump motor until you try this simple trick to see if you can get it going ...

Started pool yesterday and pump was running great and it had run almost 24 hours when I noticed it had stopped working. No lights on the display. Intelichlor generator still has power. Checked power to the drive and have 250v. Not sure what to look for as far as voltage to the keypad. Turned the impeller through the skimmer and it spins freely.February 09, 2020. Communication issues are among the most common problems people run into with their Pentair pool equipment. The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing. an Intelliflo pump won't run the schedule. screenlogic can't control the system.Solution: Inspect the display module for damage or lose connections. Replace the display module if needed. Communication Error Incorrect communication settings or configurations can cause the display to remain inactive. Check the communication protocol and settings to ensure proper configuration. Solution:The pentair intelliflo display not active error occurs when the display on the pentair intelliflo pool pump is not functioning properly. This error can be frustrating …Re: Anyone ever have the LCD screen go out on the Intelliflo My display went out the same way. The pump still worked, but the display was unreadable. Pentair replaced the display module as Jason noted without replacing the pump. Mine was replaced at the end of the season last year, and we are just opening now, so we will see how the …Consult Pentair Water Pool and Spa, Inc. with any questions regarding this product. This product is intended for use in swimming pool applications only. Most states and local codes regulate the construction, installation, and operation of public pools and spas, and theMay 30, 2020 · Bedford, TX. May 30, 2020. #4. Ben, I have never seen it say "Program1" ??? I know mine only says "Display not active" when the automation is in control. The key in my mind is if you can change a speed on the automation, and the pump responds with the right speed, then it must be working OK.. Thanks, Jim R.

PENTAIR HOME INTEIONNET ’ If you have questions about ordering Pentair replacement parts, and pool products, please contact: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service and Technical Support, USA (8 A.M. to 4:30 P.M. — Eastern/Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site …

I have the Intelliflo also. I run mine at 1100 rpm for skimming and making chlorine with the SWG. It uses 150 watts at 1100 rpm and works great. Here is how the math works 168 watts x 8 hours run = 1344 watts ÷1000 = 1.344 kWh x 30 days = 40.32 kWh x 10.25c/kWh = $4.13 per month

Jun 3, 2018 · The pump is just a little over 1 year old so past the warranty. It was installed by a professional pool company. The Pentair Intelliflo 2 VST 1.5 HP pump had been working great then abruptly just stopped after a scheduled program. There is no display at all, there were no warning alarms before it quit working either. Intelliflo VS pump is supposed to have constant power and not wired through the filter pump relay. The Intelliflo VS pump should be controlled by the RS-485 comm line. What does the Intelliflo display show? If the pump can be controlled by its control panel then the RS-485 comm control to the pump is not active.Brad, So, it would work ok for a pool tech doing a normal maintenance, like cleaning the pump basket, skimmer baskets, or filter cleanings, but it would not work well for a pool tech that is trying to troubleshoot an issue with schedules, or how the system is running.The pentair intelliflo display not working may be due to a malfunction or faulty connection. If you are experiencing this issue, ensure that the display is properly …Loose wires and a malfunctioning timer can prevent the pump from turning on and off. Tighten the wires with the previously mentioned process, then listen to the clock closely. There should be a clicking sound if the clock is working properly on an external timer. Replace the internal timer if it won’t turn off.I went out today to look at the clean cycle time settings and found the pump "locked" with "Display not Active!" on the LED screen. No buttons work, not any. I have to power off by flipping the breaker, waiting at least one minute, and I get the pump menus back. However, once running for any length of time the system locks back up.If you’ve recently experienced an issue with your Pentair Intelliflo Display not working, it’s likely due to a power failure or incorrect wiring. To get the display up and running again, check all power connections and ensure that they are properly secured. 13 years ago. reset VF to factory=. Press and hold 4 top buttons then release. Then hold down the two middle keys while holding down select and escape at the same time. At Application set up press select. To govern the pump to a 2HP or 1HP max, press the 4 top keys, arrow to PAR 699, change to 1 or 2 and power down, power up.May 27, 2019 · I would purchase the newer model that has the rotatable display. There are also flow control models that allow you to set a flow rate set-point. DO NOT GET THE SVRS (safety vacuum release system) MODEL. All IntelliFlo and WhisperFlo Pentair pumps use the same wet end design. So there should be no plumbing work necessary. Pentair intelliflo pool pump display only lasted 4 years and now the part is discontinued. ... Pentair - Display quit working after 4 years and is discontinued as ...The pump is just a little over 1 year old so past the warranty. It was installed by a professional pool company. The Pentair Intelliflo 2 VST 1.5 HP pump had been working great then abruptly just stopped after a scheduled program. There is no display at all, there were no warning alarms before it quit working either.Jun 30, 2019 · I have the ScreenLogic Config app on my iPhone. I went to the IntelliFlo Setup section and see Pump 1 and Pump 2 listed. Pump 1 is my main pump and Pump 2 is my cleaner pump. Both pumps are set to "none," which makes sense since neither was a IntelliFlo. Now that Pump 1 is an IntelliFlo, I know it's obvious that I should set it to VSF.

intellitouch® control system for pool and spa important safety instructions read and follow all instructions save these instructions user’s guideBe sure that you have power gong to pump first by checking wires with a volt meter. If the wires have power and they are properly attached to pump motor, and there is no display on the intelliflo screen then it is a bad drive. Call pentair with your invoice and serial number. Follow the number above prompts and they will get you a new pump. May 18, 2023 · Yes the RS-485 cable.. A single speed pump is controlled by an Aux relay and does not use the RS-485 com port. A VS pump is controlled by the RS-485 cable and is not wired to any Aux relay. It sometimes takes a minute or two for the "Display not Active" screen to go away when you first go into the Service mode. Instagram:https://instagram. 8 00 am bstatt outage new albany ohiocraigslist fairfield county free stuffrealidades 3 textbook pdf free The main pump screen displays IntelliFlo #2 with the assigned circuit name. INTELLIFLO Select another IntelliFlo pump and repeat step 3 to assign a circuit name. 5. When finished, press the BACK button to return to the Equipment screen. IntelliTouch Pool and Spa Control System User’s Guide... Page 69: Filtering ParametersPreventative Maintenance Can Help Prolong Pump Life. Keep your pump running as efficiently as possible and mitigate unplanned downtime by performing routine preventative maintenance. Our team has compiled a variety of resources you can use to help spot the signs that indicate your pump may need to be serviced. Preventative Maintenance Tips. moon phases for octoberfedex home delivery jobs Water Pump Pentair INTELLIFLO Operation And Set Up Instructions. (16 pages) DC Drives Pentair INTELLIFLO Installation Manual. Variable speed pump drive (4 pages) Water Pump Pentair INTELLIFLO VS+SVRS Installation And User Manual. Ultra energy efficient pump (56 pages) Water Pump Pentair IntelliFloXF Installation And User Manual. bad thinking diary chapter 44 Aug 27, 2022 · The light icon should turn green. Then go out and look at the actual light and confirm it is on. If it is on, turn the light off using the light button on the EasyTouch. Then confirm that the ScreenLogic light icon goes off. If this works, it proves that your RS-485 com port is working. Loose wires and a malfunctioning timer can prevent the pump from turning on and off. Tighten the wires with the previously mentioned process, then listen to the clock closely. There should be a clicking sound if the clock is working properly on an external timer. Replace the internal timer if it won’t turn off.3- Under mode, it will display the current program and you just have to tap either manual, timer, or schedule for whoever moe you would prefer or need. If you choose manual mode, then it must be manually started and stopped from the pump dashboard. ... 011076 Pentair IntelliFlo 3HP Pump Comparison 011056 vs 011076 Pentair IntelliFlo3 …